Air Stream(±â·ù)¸¦ ÀÌ¿ëÇÑ ³Ã°¢ ¼øÈ¯ÀåÄ¡·Î 20scfmÀÇ °ÇÑ ±â·ù·Î Á¤È®ÇÑ ¿ÂµµÁ¶Àý ¹× ºü¸¥ ¿Âµµº¯È¯ÀÌ °¡´ÉÇϸç, 1600¡É/minÀÇ ºü¸¥ ¼Óµµ·Î -80~350¡É±îÁö ¿Âµµ Á¶ÀýÀÌ °¡´ÉÇÏ´Ù.
ÁÖ·Î NMR, XRD, MRI, ESRµî Á¤¹ÐºÐ¼® ÀåºñÀÇ ³Ã°¢¿¡ »ç¿ëÀÌ µÈ´Ù.
XR AirJet
• NMR, X-Ray Crystallography, EPR
• -80C or -40C to +100C temperature range
• Small footprint - can be rack mounted if required
• 8, 15 or 35 ft (248.84, 457.20 or 1066.80 cm) non magnetic delivery line
• Flow rates 1 scfm (28 lpm)
• +/-0.1C temperature stability

SP Scientific»çÀÇ Controlled Rate Freezer´Â ÁÖ·Î Tissue Freezing½Ã¿¡ ¸¹ÀÌ ÀÌ¿ëÀÌ µÇ¸ç, Mechanical Refrigerated Cooling systemÀ¸·Î½á ¾×üÁú¼Ò³ª µå¶óÀ̾ÆÀ̽º °°Àº º°µµÀÇ ³Ã¸Å¸¦ °ø±ÞÇÏÁö ¾Ê¾Æµµ ³Ã°¢ÀÌ °¡´ÉÇϹǷΠÆí¸®ÇÏ°Ô »ç¿ë °¡´ÉÇϸç, º°µµÀÇ Ãß°¡ºñ¿ëÀÌ ¹ß»ýÇÏÁö ¾Ê¾Æµµ µÈ´Ù. ÁÖ·Î Á¶Á÷ÇÐ ¹× º´¸®ÇÐ ºÐ¾ß¿¡¼ ¸¹ÀÌ »ç¿ëÀÌ µÈ´Ù.
Bio-Cool
• 1.5 liter stainless steel bath
• Built in magnetic stirrer with vortex breaker
• Temperature of -40C or -80C
• Control resolution of 0.1C, accuracy of +/- 0.2C and stability of +/-0.1C
• Mechanically refrigerated, no expendable refrigerants utilized
• RS-232 Interface available on BC-III

SP Scientific»çÀÇ Immersion Probe´Â Àüü Áß ÀϺκÐÀÇ ³Ã°¢(Spot cooling)ÀÌ ÇÊ¿äÇÑ °æ¿ì¿¡ À¯¿ëÇÏ°Ô »ç¿ëÀÌ µÈ´Ù. Àåºñ¿¡ ¿¬°áµÈ Cooling Probe´Â ³Ã°¢À» ½Ã۰íÀÚ ÇÏ´Â ¿ë¾×À̳ª Á¢Ã˸鿡 Á÷Á¢ Á¢ÃËÇÏ¿© ³Ã°¢ÀÌ °¡´ÉÇϸç, Laboratory Dewar, Vapor trap, »þ¸£ÇÇÃæ°Ý½ÃÇè±â (Charpy Impact Tester), ½ÃÂ÷Áֻ翷®°è(DSC) µîÀÇ ³Ã°¢¿¡µµ »ç¿ëÀÌ °¡´ÉÇÏ´Ù. ³Ã°¢¿Âµµ´Â ÃÖ´ë -100¡É±îÁö °¡´ÉÇÏ´Ù.
Flexi-Cool
• Direct expansion of refrigerant in probe creates temperatures of -50C or -100C at the probe
• Heat removal of up to 750 BTUs (configuration and temperature dependent)
• Choice of three style probe configurations
• Small compact size for spot cooling
• Mechanically refrigerated
• PID control with external sensor
• RS232 Interface

SP Scientific»çÀÇ Low Temperature Bath´Â ³Ã°¢¾×À» ÀÌ¿ëÇÏ¿© ³·Àº ¿ÂµµÁ¶°ÇÀ» Á¦°øÇÔÀ¸·Î½á ´Ù¾çÇÑ ÀÀ¿ëºÐ¾ß¿¡¼ »ç¿ëÀÌ °¡´ÉÇÏ´Ù. ¶ÇÇÑ ÀÌ ½Ã½ºÅÛÀº Mechanical refrigerated systemÀ¸·Î½á ¾×üÁú¼Ò³ª µå¶óÀ̾ÆÀ̽º °°Àº °ªºñ½Ñ ³Ã¸Å¸¦ »ç¿ëÇÏÁö ¾ÊÀ¸¹Ç·Î º°µµÀÇ À¯Áöºñ¿ëÀÌ µéÁö ¾Ê´Â ÀåÁ¡ÀÌ ÀÖ´Ù. 4¸®ÅÍ¿Í 8¸®ÅÍ ¿ë·®ÀÇ µÎ °¡Áö ¸ðµ¨ÀÌ ÀÖÀ¸¸ç, -80~100¡ÉÀÇ ¿Âµµ¹üÀ§¿¡¼ »ç¿ëÀÌ °¡´ÉÇÏ´Ù.
HistoChill
• Mechanically refrigerated
• rost reduction loop
• Hinged & insulated chamber lid
• Small footprint tabletop design
• Operates on standard 120 volt or 220 volt power sources
Multi-Cool
• 4 or 8 liter stainless steel bath
• Built in magnetic stirrer with vortex breaker
• Mechanically refrigerated, no expendable
refrigerants utilized
• Temperatures from -80C to +100C
• Control stability of +/-0.1C
• RS-232 Interface
|